 Solid State Relays G3@-VD
G3H/G3HD
CSM_G3H_G3HD_DS_E_3_1
New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays
* Certified by UL, CSA, and VDE (models numbers with a suffix of "-VD"). * Socket type, same size as LY Power Relays. * Operation indicator provided to confirm input (models numbers with "N" before the suffix).
Refer to Safety Precautions for All Solid State Relays.
Model Number Structure
Model Number Legend
G3H-@@@@@@-@
1
1. 2.
2 34 5 67
8
6. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, and VDE standards
Basic Model Name G3H: Solid State Relay Rated Load Power Supply Voltage 2: 200 VAC 03: 3A
7.
3, 4. Rated Load Current 5. Terminal Type S: Plug-in terminals 8.
G3HD-@@@@-@
1
1. 2. 3. 4.
2
34 5 6 7
5. 6. Terminal Type S: Plug-in terminals Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator Certification VD: Certified by UL, CSA, VDE
Basic Model Name G3H: Solid State Relay Load Power Supply Type D: DC Rated Load Power Supply Voltage X: 50 VDC Rated Load Current 03: 3A
7.
1
G3H/G3HD
Ordering Information
List of Models
Isolation Photocoupler Phototriac coupler Yes No Zero cross function Yes Indicator Rated output load 3 A at 100 to 240 VAC (See note 1.) Rated input voltage 5 to 24 VDC 5 VDC 12 VDC 24 VDC Photocoupler Photocoupler Phototriac coupler --Yes No No 3 A at 4 to 48 VDC (See note 2.) 3 A at 100 to 240 VAC (See note 1.) 5 to 24 VDC 4 to 24 VDC 5 VDC 12 VDC 24 VDC Photocoupler Photodiode array Note: 1. 2. 3. 4. ----Yes 3 A at 4 to 48 VDC (See note 2.) 2.5 A at 24 to 240 VDC (See note 3.) 4 to 24 VDC 12 to 24 VDC G3HD-X03S-VD G3HD-202SN-VD G3HD-X03SN-VD G3H-203S-VD G3H-203SL-VD Model G3H-203SN-VD G3H-203SLN-VD
Product is labelled "240 VAC". Product is labelled "48 VDC". Product is labelled "240 VDC". When ordering, specify the rated input voltage.
Accessories (Order Separately)
Connecting Sockets
Item Connecting Mounting method/ Terminal type Hold-down clip PTF08A-E Front connecting Track mounted screw terminals PYC-A1 PT08 Back connecting Solder terminals PYC-P PCB terminals Wire-wrapping terminals PT08-0 PT08QN
Specifications
Ratings (at an Ambient Temperature of 25C)
Input
Model G3H-203SN-VD Rated voltage 5 to 24 VDC 12 VDC 24 VDC G3HD-X03SN-VD 5 to 24 VDC G3H-203S-VD G3H-203SL-VD 4 to 24 VDC 5 VDC 12 VDC 24 VDC G3HD-X03S-VD 4 to 24 VDC G3HD-202SN-VD 12 to 24 VDC Operating voltage 4 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 4 to 28 VDC 3 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 3 to 28 VDC 9.6 to 28.8 VDC Impedance 15 mA max. (See note 2.) 390 20% 900 20% 2 k20% 15 mA max. (See note 2.) 390 20% 900 20% 2 k20% 25 mA max. (at 24 VDC) (See note 2.) 4 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 1 VDC min. 1 VDC min. 1 VDC min. 3 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 1 VDC min. 1 VDC min. 9.6 VDC max. Voltage level Must operate voltage G3H-203SLN-VD 5 VDC Must release voltage 1 VDC min. 1 VDC min.
1.5 k +20%/-10% (See note 1.) 4 VDC max.
1.5 k +20%/-10% (See note 1.) 3 VDC max.
Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays. 2. With constant current input system.
2
G3H/G3HD
Output
Model Rated load voltage G3H-203SN-VD G3H-203S-VD G3H-203SLN-VD G3H-203SL-VD G3HD-X03SN-VD G3HD-X03S-VD G3HD-202SN-VD 4 to 48 VDC 24 to 240 VDC 3 to 52.8 VDC 19.2 to 264 VDC 0.1 to 3 A at 40C 0.001 to 2.5 A at 40C 18 A (10 ms) 20 A (10 ms) 100 to 240 VAC 75 to 264 VAC Applicable load Load voltage range Load current 0.1 to 3 A at 40C Inrush current 45 A 60 Hz, 1 cycle
Characteristics
Model Operate time Release time G3H-203SN-VD/203S-VD G3H-203SLN-VD/203SL-VD G3HD-X03SN-VD/X03S-VD 1/2 cycle of load power source + 1 ms max. 1 ms max. 0.5 ms max. 2 ms max. G3HD-202SN-VD 5 ms max. 10 ms max. 3 V max. (output ON-resistance: 1.25 max.) 5 mA max. (at 50 VDC) 0.1 mA max. (at 200 VDC)
1/2 cycle of load power source + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max. Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Certified standards EMC Weight 5 mA max. (at 100 VAC); 2.5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) 5 mA max. (at 200 VAC) 100 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Destruction: 1,000 m/s2 Operating: -30C to 80C (with no icing) Storage: -30C to 100C (with no icing) 45% to 85% G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Approx. 50 g
1,500 VAC, 50/60 Hz for 1 min
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3H-203SN-VD/203S-VD/203SLN-VD/ 203SL-VD G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD
Load current (A) 4 G3H-203SN-VD, G3H-203S-VD G3H-203SLN-VD, G3H-203SL-VD G3HD-X03SN-VD, G3HD-X03S-VD 3 2.5 2 G3HD-202SN-VD 1.5 1 10 20
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3H-203SN-VD/203S-VD/203SLN-VD/ G3H-203SL-VD
G3HD-X03SN-VD/X03S-VD G3HD-202SN-VD
Inrush current (A, Peak)
50
Inrush current (A)
30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 10 G3HD-X03SN-VD G3HD-X03S-VD G3HD-202SN-VD
40
30
0 -30 -20
0
20
40
60
80
100
0 10
30 50 100 200
500 1,000
5,000
20 30
50 70 100
200 300 500 1,000 2,000 Energized time (ms)
Ambient temperature (C)
Energized time (ms)
3
G3H/G3HD
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/ Internal Connections (Bottom View)
1 28 max. 3 5 21.5 max. 36.5 max. 42.5 max. - 7 - Input voltage
Load
2 4(+) 6(-) 8 + +
Load Load power supply
(+)
(
(-)
)
Input
Note: 1. The plus and minus symbols shown in the parentheses are for DC loads. 2. The coil has no polarity.
Safety Precautions
Precautions for Correct Use
Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance.
EMC Directive Compliance
1. AC-switching models comply with EMC Directives under the following conditions ("-VD" models only).
Less than 3 m Load Input G3H-VD Output
Connection
The SSR for DC switching use can connect to a load regardless of the polarity of the positive and negative output terminals.
Varistor: 470 V, 0.6 W Film capacitor: 1 F, 250 VAC
Varistor
Film Capacitor
Close Mounting of Multiple Relays
If multiple Relays are mounted side by side, be aware that the outer wall of each SSR works as a heat sink. The SSR casing serves to dissipate heat. Install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
* Connect a varistor between the output terminals. * Connect a film capacitor to the load power supply. * The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the following conditions ("-VD" models only).
Less than 10 m Load Input G3HD-VD Output
Protective Terminal
No overvoltage absorption element is built in. (The G3HD-202SN has a built-in varistor.) Be sure to connect an overvoltage absorption element when using the G3H or G3HD with an inductive load.
* The input cable must be less than 10 m.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2009.1 In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2009 All Right Reserved.


▲Up To Search▲   

 
Price & Availability of G3H-203SN-VD

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X